Quality Checks for Processed Glass Panels Made in China

Check custom glass panels from China against the drawing and an approved sample, and inspect the consignment on site before it leaves the factory. Agree the checks before production starts: size, edge work, holes or cut-outs, chips and scratches, flatness, and any print alignment. Safety glass rules differ by country and by use, so name the standard your panels must meet when you send the drawing.

Roclin Global Sourcing is a sourcing and quality management company based in Zhuhai and does not own the factories. Glass work it arranges includes computer numerical control (CNC) and waterjet cutting, printing, tempering and heat strengthening, laminating and curving. These processes can be combined to match the drawing. Every panel is made to the customer’s drawing, rather than chosen from a catalogue. Roclin does not publish a standard catalogue. It supplies small and medium-sized manufacturers and building contractors in the United Kingdom (UK), Ireland, Australia, Canada, New Zealand and Western Europe. Roclin reviews the drawing and samples with the factory, inspects consignments on site before they leave China, and arranges shipping to your door.

Roclin does not claim certification to a named safety glass standard on this site. Tell us the standard required for your market, and we will review the drawing and samples with the factory.

What to agree before production

Send the drawing or a clear sketch, with sizes, glass type and thickness, edge work, holes or cut-outs, and any printing, tempering or laminating needed. Add the quantities, how often you expect to order, the delivery country, and any packing, marking or inspection needs. Email info@roclin.com, or call +86 756 3210 990. There is a fuller list on the processed glass panels page and the contact page.

Write down the checks the consignment must pass, and what happens if a panel fails. Inspection follows the drawings, the samples and the checks agreed for that job.

Common checks

The list below is a practical starting point from Roclin’s inspection experience.

  • Size and squareness, against the drawing and the agreed tolerance
  • Thickness and glass type
  • Edge work (for example flat polish, arris, or another edge you have specified)
  • Holes and cut-outs: position, diameter and quality of the edge
  • Edge chips and shelling
  • Scratches, rubs or marks on the face
  • Flatness, bow or visible warp
  • Print or coating alignment, colour and coverage, if the panel is printed or coated
  • For tempered or heat-strengthened glass, any visible bow or roller marks you have agreed to limit
  • For laminated glass, alignment of the sheets and appearance of the interlayer, against the sample
  • Quantity, marking and any logo or label you required

Do not treat this list as complete for every product. A shower panel, a printed splashback and a curved laminated panel will not share the same checks.

Samples

Approve a sample before production, especially for printed, coated, curved, tempered or laminated work, and for any new hole or edge detail. The sample is how you agree appearance as well as size.

If a measurement or finish is not yet decided, say so at quote stage. Judge the sample in the lighting you will use to judge the production panels.

On-site inspection before shipping

Roclin inspects consignments on site before they leave China, so problems can be fixed at the factory rather than after delivery. Inspection follows the drawings, the samples and the checks agreed for that job. During production, Roclin manages the order. After inspection, it arranges shipping from the factory through to your door.

If you want extra checks, or a particular inspection method, include them when you send the drawing.

Packing for transport

Glass needs packing that protects edges and faces in transit. Stackable wooden crates are the most common packing method for glass. Roclin has also used reusable metal stillages successfully.

If you have a packing specification, send it with the drawing. If you do not, say if the panels will be handled again before they reach the end user, and whether they ship as a full crate to one site or as smaller packs. We will agree packing for the job when we plan the shipment.

Safety glass standards by market

Tempering, heat strengthening and laminating are part of Roclin’s glass work. Roclin supplies customers in the UK, Ireland, Australia, Canada, New Zealand and Western Europe. Safety glass rules differ by country and by use. Name the standard your panels must meet on the drawing or in the brief.

The tables below list common official standards for ordinary building glass in those markets. They do not include fire-resistant glass, or bullet-, blast- or attack-resistant glass. Links go to the official standards body or catalogue listing. They are not a claim that Roclin or a factory is certified.

Roclin does not claim certification to a named safety glass standard on this site. Tell us the standard required for your market, and we will review the drawing and samples with the factory. If your market uses a different standard, name that standard instead.

Building rules, such as Australia’s National Construction Code or the New Zealand Building Code, may also apply, depending on the use.

Australia and New Zealand

DesignationTitleOfficial listing
AS/NZS 2208:2023Safety glazing materials in buildingsStandards Australia
AS 1288:2021Glass in buildings — Selection and installationStandards Australia
AS/NZS 4667:2000 (reconfirmed 2016)Quality requirements for cut-to-size and processed glassStandards Australia
AS 4666:2012Insulating glass unitsStandards Australia

AS/NZS 2208 is a joint Australian/New Zealand standard. AS 1288 is the Australian selection and installation standard. AS 4666:2012 was redesignated from AS/NZS 4666:2012 after an Australia-only amendment in 2018.

New Zealand’s own glazing standard is NZS 4223, Glazing in buildings, listed by Standards New Zealand and on Building CodeHub. The current parts are:

  • NZS 4223.1:2008, Code of practice for glazing in buildings — Glass selection and glazing (Building CodeHub)
  • NZS 4223.2:2016, Glazing in buildings — Part 2: Insulating glass units (Building CodeHub)
  • NZS 4223.3:2016, Glazing in buildings — Part 3: Human impact safety requirements (Building CodeHub)
  • NZS 4223.4:2008, Glazing in buildings — Part 4: Wind, dead, snow, and live actions (Building CodeHub)

Europe and the United Kingdom

The United Kingdom adopts the European standards below as BS EN or BS EN ISO. Links are to the official BSI or ISO catalogue listings, which use the same titles as CEN. These standards are published in parts; the titles below are the series titles (for example, EN 12150-1 is Part 1, Definition and description).

BS 6262, Glazing for buildings, is the UK code of practice for selecting glazing, including safety related to human impact (BS 6262-4).

DesignationTitleOfficial listing
EN 572Glass in building — Basic soda-lime silicate glass productsBSI, BS EN 572-1
EN 1096Glass in building — Coated glassBSI, BS EN 1096-1
EN 12150Glass in building — Thermally toughened soda lime silicate safety glassBSI, BS EN 12150-1
EN 14179Glass in building — Heat soaked thermally toughened soda lime silicate safety glassBSI, BS EN 14179-1
EN 1863Glass in building — Heat strengthened soda lime silicate glassBSI, BS EN 1863-1
EN ISO 12543Glass in building — Laminated glass and laminated safety glassISO 12543-1
EN 14449Glass in building — Laminated glass and laminated safety glass — Evaluation of conformity/Product standardBSI, BS EN 14449
EN 12600Glass in building — Pendulum test — Impact test method and classification for flat glassBSI, BS EN 12600
EN 1279Glass in building — Insulating glass unitsBSI, BS EN 1279-1

Canada

DesignationTitleOfficial listing
CAN/CGSB-12.1-2026Safety glazingGovernment of Canada Publications
CAN/CGSB-12.8-2026Insulating glass unitsGovernment of Canada Publications

CAN/CGSB-12.20, Structural design of glass for buildings, has been withdrawn and is not listed here.

AAMA/WDMA/CSA 101/I.S.2/A440, North American Fenestration Standard/Specification for windows, doors, and skylights, published by CSA Group, applies to complete fenestration products, not to individual processed glass panels. Name it only if you are buying a complete window, door or skylight.

Bathroom and shower glass

Bathroom work has long been part of Roclin’s business. The company timeline includes helping a manufacturing client win a major new market through new materials in showers, and a published case study on high-end bathroom components from China. Send drawings for shower screens, panels or other bathroom glass and we will advise.

See also what we make, how we work and logistics.

Questions and answers

How is the glass checked before it ships?

We review the drawing and samples with the factory before production. During production we manage the order, and we inspect consignments on site before they leave China, so problems are fixed at the factory rather than after delivery. We then arrange shipping from the factory through to your door.

What should we send for a processed glass quote?

Send the drawing or a clear sketch, with sizes, glass type and thickness, edge work, holes or cut-outs, and any printing, tempering or laminating needed. Add the quantities, how often you expect to order, the delivery country, and any packing, marking or inspection needs. If something is not decided yet, say so and we will tell you what else we need.

Can you supply tempered or laminated safety glass for the UK or Australia?

Yes, tempering, heat strengthening and laminating are part of our glass work, and we supply both markets, as well as Canada, New Zealand and our other markets. Safety glass rules differ by country and by use, so tell us the standard your panels must meet when you send the drawing. Common official standards are listed in the tables above. We review the drawing and samples with the factory, and inspect consignments on site before they leave China. We do not claim certification to a named standard on this site.

What defects should I look for?

Agree the list before production. A practical starting point, from our inspection experience, is size, thickness, edge work, holes and cut-outs, edge chips, scratches, flatness, and print alignment if the panel is printed. Add any extra checks that apply to tempered, laminated or curved glass. Confirm the list against your drawing and sample.

How is glass packed for export?

Stackable wooden crates are the most common packing method for glass. We have also used reusable metal stillages successfully. If you have a packing specification, send it with the drawing. We will agree packing for the job when we plan the shipment.

Do you claim certification to a named safety glass standard?

No. We do not publish a certification claim on this site. Name the standard your market requires, and we will review the drawing and samples with the factory.